HomeAbout UsPDM ServicesEquipment SalesTrainingCase StudiesArticlesFAQContact Us

 

YOUR PREDICTIVE MAINTENANCE SOLUTIONS

 

 

   

Featured Article of the Month

 

“Using Infrared to Stamp Out Grow-Ops “

By Brian Jastrow, CET, LEVEL III CERTIFIED THERMOGRAPHER

President, InfraRed Imaging Solutions Inc. (IRIS)

The risks are low, the potential profits are mind boggling.

These are the two factors that are fueling the grow ops industry in the GTA.   Toronto police say that because the city’s vacancy rate is near an all time high, apartment buildings have become a preferred location for marijuana growers.

“The  trend we are seeing is that they are using apartment buildings because of extremely high vacancy rates and availability” says Det. Sgt. Dave Malcon of the Toronto Police Service Drug Squad.  The average vacancy rate in 2005 was 3.7 percent in Toronto, according to CMHC.

One of the larger advantages for growers is that many apartment buildings have a single hydro meter for the entire building, enabling extraordinary electricity consumption without being detected by Toronto Hydro. Not only do these  grow operations pose a serious fire and health risk to neighbors unknowingly forced to breathe in potentially harmful mould spores and  spores from the fertilizer used to grow the plants, some are heavily guarded by booby traps and armed gang members.

Growers beware… infrared thermography can detect your high electricity use by thermally inspecting the hallway electrical distribution panels.  Basically an average size unit will be equipped with an 80 Amp or 100 Amp double pole circuit breaker. When the growers are unplugging the 220 Volt  stove outlet and running their 1000 Watt lighting systems  for  long periods of time  this will be detected as a thermally  anomaly  on the individual circuit  breaker due to the fact that these lights will create excessive amp loading  which should not exceed 80% of the circuit capacity. For example, an 80 Amp double pole circuit breaker should not have more than 64 Amps maximum load. High end thermal imagers will detect this thermal pattern and transpose it into a thermograph, basically a digital image of the hot breaker.

If building owners and managers want an upper hand in fighting this situation, they should invest in hiring a certified Thermographer.

 

Click to download excellent maintenance proactivity articles. (PDF)

Infrared Best Practices

By: Terrence O’Hanlon, Reliabilityweb.com  

 

Keys to a Good Inspection Program

By: Mark B. Goff, P.E., Tennessee Valley Authority

 

Integrating Ultrasound and Vibration Technologies, Each Achieves More

By: Liane Emata-Harris, InfraRed Imaging Solutions 

 

Direct Reading and Analytical Ferrography

By: Bill Quesnel, Wear Check Canada

Troubleshooting Paper Machine Problems through Thermal Imaging

By: Robin Thon, Albany International Corp.

Manage Energy - Save Our Environment

By: Liane Emata-Harris, InfraRed Imaging Solutions Inc. (IRIS)

Engine Troubleshooting Checklist

By; Wear Check Africa

Automated Bearing Wear Detection

By: Alan Friedman, DLI Engineering

Condition Monitoring, Oil Analysis and More

By: Jan Backer, Wear Check Africa

Diagnostics: Evolution in the Revolution
By: Alan Friedman - September 2005 Issue of Pumps & Systems magazine

Accelerometer Overload

By: K.C. Dahl, DLI Engineering

 

 

 

Copyright 2006 InfraRed Imaging Solutions Inc. (IRIS). Designed by IRIS.

 

More about Roof Inspections